Beckett GeniSys Contractor Tool Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Beckett GeniSys Contractor Tool. Beckett GeniSys Contractor Tool User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Description / Applications
The Beckett GeniSys
TM
Display is an optional attachment for the
GeniSys Primary Control that allows a technician to monitor and
program the primary control variables. The Beckett GeniSys
TM
Contractor Tool is a rugged hand-held version of the display
module for use by service engineers. The screen on both the
Display and the Tool show current burner status, control timings,
and burner cycle history. The display and tool programming
mode allows a technician to customize both the pre-time and
post-time settings. When the Display remains on the burner, a
lockout service message can be programmed that displays a
custom message.
for the GeniSys Advanced Burner Control
GeniSys
Display
or
Contractor’s Tool
PARTS & ACCESSORIES
This tool is NOT intended for use
on any other Non-GeniSys Control
or Equipment.
Non-intended usage can cause damage to the Contractor
Tool, or the control being tested and potentially alter control or
system operation.
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Contractor’s Tool

Description / ApplicationsThe Beckett GeniSysTM Display is an optional attachment for the GeniSys Primary Control that allows a technician to monitor

Pagina 2 - Specifi cations

Page 10Screen Message Sensor/Monitor/MessageNotes/Checks### ohms avg Cad Cell Historical cycle data located in Control. Average Cad Cell resis-tance

Pagina 4 - B. Burner Cycle History

Form No. 61687 R04, Printed in USA 06/09CORPORATIONUSA: P.O. Box 1289 ● Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876)Canada: R.W. Beckett

Pagina 5

Page 2InstallationWith a slotted screwdriver, carefully remove the COM2 port cover on the right side of the GeniSys control. When installing the displ

Pagina 6 - Cycle End Reason*

Page 3The display was designed to function as both a monitor and a programmer. The display consists of two rows of 16 alphanumeric characters. Below

Pagina 7

Page 4Standby - During this time, the burner is idle and waiting for a signal to turn on.Pre-time - The Pre-time screen will display the number of sec

Pagina 8

Page 5Pressing the BACK (NO) key at this stage will return the display to the VIEW HISTORY screen. Pressing the PREV key will display the hours since

Pagina 9 - 

Page 6►NEXTCycle End Reason* * The possible cycle end reasons are as follows, Recycled - The burner was shut down bec

Pagina 10 - Information Chart

Page 7To return to the CYCLE HISTORY screen, press BACK (NO) once. To return to the BURNER HISTORY screen, press BACK (NO) a second time. C. Pre-time

Pagina 11 - Page 11

Page 8D. Post-time Set ProgramFrom the PRE-TIME, SELECT TO CHANGE screen, press the NEXT key to access the POST-TIME (motor off delay), SELECT TO CHAN

Pagina 12 - WARRANTY

Page 9E. Service Message ProgramFrom the POST-TIME CHANGE screen, pressing the NEXT key will display the SERVICE MESSAGE, SELECT TO CHANGE programmin

Comentarios a estos manuales

Sin comentarios