SPECIFICATIONS
PACITIES MODEL SF
...............................
2.50 to 5.50 gallons per hour
..............................
350,000 to 770.000 BTUIHR Input
See SPECIAL AIR TUBE COMBINATIONS DETAILS For
Special Firing Rates
FUELS
No. 1 or No. 2 Heating Oil (ASTM
D396) Only
In Canada. No.
1
or No. 2 Furnace Oil
DIMENSIONS (Standard)
Height
................................................
13-518"
Width
.................................................
15-318''
Depth (Chassis Only)
...................................
8-112"
..............................
I
ELECTRICAL CHARACTERISTICS (See Note)
..............................
Power Supply.
:
115 Vl60 Hz 1 PH
.........
Operating Load. (Max.) 7.1 Amps
Motor.. 114 HP 3450 RPM. N.E.M.A. "N" Flange, manual
reset. overload protected
Ignition.
.................
10,000 V123 ma secondary, continuous
duty, shielded transformer or solid-state ignition system
FUEL UNlT
INSTRUCTION MANUAL
OIL BURNER
Dear Homeowner:
Over forty years of engineering and product development have
gone into your new oil burner. Its quality and
des~gn are unsur-
passed. Properly installed and maintained it
will
provide many years
of efficient, trouble-free operation. Please read
this
lnstructlon
M?nual
carefully, and give special attent~on to the
following
points.
-
An oil burner must have a generous supply of
combustion
air
to
operate properly. Please refer to the information in this manual for
details.
- NEVER attempt to use gasoline
In
your heating applmce. Gaso-
line is more combustible than fuel oil and could result in a
serlous
explosion. NEVER burn garbage or refuse In your heatlng appll-
ance
or try to light oil by tossing burning mater~al into the heater
-
INSTALLATION AND ADJUSTMENT OF THE BURNER REQUIRES
TECHNICAL KNOWLEDGE AND THE USE OF COMBUSTION
TEST INSTRUMENTS. DO NOT TAMPER WlTH THE
UNlT OR
CONTROLS. CALL YOUR SERVICEMAN.
Beckett warrants its equipment specifically to those who have pur-
chased it for resale. including your dealer. In the even: of any prob-
lems with your equipment or its installation, you should contact your
dealer for assistance.
...............................................................
Suntec, or Webster
NOTE:
50
Hertz electrical components are available on special order.
TO THE INSTALLER
Underwriter's Laboratortes hascert~f~ed thls burner to comply w~th the
commerc~al standards CS75, and has listed it for use w~th
P
1 or
u2
fuel
011 as spec~fled In ASTM
D396.
State and lccal approvals are shown on
burner rating label. The burner is
certif~ed In Canada by CanadIan
Standards Association (CSA). All oil burners should be ~nstalled ~n
INSTALLATION OF THE BURNER MUST BE DONE BY A QUALIFIED
INSTALLER IN ACCORDANCE WlTH REGULATIONS OF THE
NATIONAL ARE PROTECTION STANDARD FOR OIL-BURNING
accordance with regulations of the National Fire
Protection
Assoc~a-
tion
pamphlet
#31
and In complete accordance w~th all local codes
and authorities having jurisdiction. Regulation of these author~t~es
take precedence over the general instruct~ons prov~ded In
this
~nstal-
lation
manual. For recommended
installation
pracllce In Canada.
reference should be made to CSA Standard
B
139
EQUIPMENT, NFPA NO. 31, AND IN COMPLETE ACCORDANCE
WlTH ALL LOCAL CODES AND AUTHORITIES HAVING JURISDIC-
TION. FOR RECOMMENDED INSTALLATION PRACTICE IN
CANADA, REFERENCE SHOULD BE MADE TO CSA STANDARD
8139.
A QUALIFIED INSTALLER IS AN INDIVIDUAL OR AGENCY WHO IS
RESPONSIBLE FOR THE
INSTAL.LATION AND ADJUSTMENT OF
THE EQUIPMENT AND WHO IS PROPERLY LICENSED AND EXPE-
RIENCED TO INSTALL OIL-BURNING EQUIPMENT IN ACCORD-
ANCE WlTH ALL CODES AND ORDINANCES.
A properly designed chimney of adequate size and height and ade-
auate combustion air
SUDD~Y
are essentials tor the best o~eration
.-
-
01 any heating plant.
When installing the heater and/or burner be sure to provide ade-
quate space for easy service and maintenance.
CONCEALED DAMAGE
If any damage to the burner or controls is found during
unpack~ng
notify the carrier at once and file the appropriate clam
1
Form
6104
BSF-R1192
Printed in
U.SA
R.W.
BECKETT
CORPORATION
P.O.
Box
1289,
Elyria, Ohio 44036,
R.W.
BECKETT
CANADA, LTD
430 Laird, Unit
3,
Guelph, Ontario,
N1
G
3x7
Vista de pagina 0
1 2 3 4 5

Indice de contenidos

Pagina 1 - BECKETT

SPECIFICATIONS PACITIES MODEL SF ... 2.50 to 5.50 gallons per hour ... 350,000 to 770.000 BTUIH

Pagina 2 - 'A"

GENERAL INFORMATION FUEL UNITS & TUBING INSTALLATION Burners are most commonly installed with a single stage fuel unit. This fuel unit

Pagina 3 -

HOMEOWNER INFORMATION 3. Check ~n~t~al alr adjustment. Normally the bulk air band (3) should be closed and the shutter (21 part~ally open: 4. Clo

Pagina 4

AIR TUBE COMBINATION DnAlLS #,L8, = oAu + 5/8" "R" = "A" + 2-7/8" "S" = 2-5/16" SEE BELOW-+ ELECTRODE

Pagina 5

PARTS /c \ WHEN ORDERING PARTS - STATE BURNEU MODEL, PART DESCRIPTION AND PART NUMBER REF DESCRIPTION PART # 18 Air Tube Combination ....