UV FILTER PUMP KIT INSTRUCTIONS
MODEL: M130UV
92095
Rev. C
CAUTION!
Do not look directly at UV lamp.
As the pump circulates water through the filter the UV exposure produces clean clear water.
Beckett pumps are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions and warnings in
this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference.
Performance: 130GPH Power Requirements: 120V,60Hz,13 Watts
Shut off (max): 4.3ft Cord Length: 16ft
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAVE THIS MANUAL FOR FUTURE REFERNCE
WARNING
The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying water pumps. See your electrical
supplies dealer for this device.
Do not remove the grounding pin from the plug.
Do not connect to any voltage other than shown on the pump.
Do not pump flammable liquids.
Do not use with water above 86º Fahrenheit (30ºC).
To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
Risk of electrical shock. This pump is supplied with a grounding conductor and ground attachment plug. To reduce the risk of electric shock, be certain
that it is connected only to a properly grounded, grounding-type receptacle.
Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop”. This will prevent water from running down the cord into the
electrical outlet.
Never directly touch the UV bulb – oil from your fingers can shorten bulb life.
If the UV’s internal components get wet, unplug the unit immediately.
Do not operate the UV Assembly with a missing or damaged Quartz sleeve.
The pump cover is provided with an interlock to reduce the risk of excessive ultraviolet radiation. Do not defeat its purpose or attempt to service without
removing the screen cover completely.
CAUTION
Always disconnect from electrical outlet before handling the pump.
Do not let the pump run dry.
Do not lift the pump by the power cord.
Do not pump heated liquids.
Operate in freshwater only.
Operate pump completely submerged for proper cooling.
Do not look directly at UV lamp.
ATTENTION
In order to get best results, operate pump completely submerged. Keep
the water level above the top of the pump at ALL TIMES.
Parts Detail:
1) Enclosure housing
2) Grid
3) Volute Cover
4) O-rings
5) Impeller
6) Cap with power cord
7) 3 watt UV bulb (E17)
8) Quartz Glass
9) Rubber Seal
10) Seal Nut
Vista de pagina 0
1 2 3 4 5 6 7

Indice de contenidos

Pagina 1 -

UV FILTER PUMP KIT INSTRUCTIONS MODEL: M130UV 92095 Rev. C CAUTION! Do not

Pagina 2 - MAINTENANCE

` LIMITED WARRANTY Each Beckett Corporation (“Beckett”) product is warranted to be free f

Pagina 3 - MODELO: M130UV

ADVERTENCIA  El Código Nacional de Electricidad exige que se utilice un tomacorrient

Pagina 4 - MANTENIMIENTO

MANTENIMIENTO Antes de llevar a cabo cualquier mantenimiento siempre desconecte la unidad entera. Si alguna toma de entrada se encuentra obstruida o

Pagina 5 - AVERTISSEMENT!

INSTRUCTIONS : TROUSSE DE POMPE PARA UV FILTRE

Pagina 6 - ENTRETIEN

ENTRETIEN Avant de procéder à des travaux d’entretien, débranchez toujours l’appareil. Une grille d’aspiration obstruée ou

Comentarios a estos manuales

Sin comentarios