RESIDENTIAL BURNERSPotential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner:Please read and carefully follow all instruct
10Fuel supply below the level of the burnerWhen the fuel supply is more than eight feet below the level of the burner, a two-pipe fuel supply system i
11NX Burner ManualIf the thermostat short cycles or operates improperly, it may require an isolation relay for proper operation. The Beckett A/C Read
12Section: Burner ControlBurner ControlSequence of Operation - GeniSys 7505.Refer to the appliance manufacturer’s wiring diagram for actual specifi cat
13NX Burner ManualTable 5 - Status LightsLight Color On Continuously FlashingRed Restricted (Hard) Lockout Soft LockoutGreenFlame Sensed during normal
14fi ring, the control shuts down the burner, enters a 60 second recycle delay, and then repeats the above ignition sequence. If fl ame is lost three ti
15NX Burner ManualPointerZero SettingLocking NutAdjustmentScrewAm52000Section: Start the Burner and Set CombustionStart the Burner and Set CombustionS
16Section: Start the Burner and Set CombustionNX Air Tube & Head CombinationsHead/Air SettingLG - (9-slot head)LH - (6-slot head)LB - (9-slot head
17NX Burner ManualSet Combustion with Test InstrumentsAllow the burner to run for approximately 5 to 10 minutes.Set the stack or over-fi re draft to th
18Section: Perform Regular MaintenanceDO NOT TAMPER WITH THE UNIT OR CONTROLS - CALL YOUR QUALIFIED SERVICE TECHNICIAN OR SERVICEMAN.To ensure continu
19NX Burner ManualSection: Perform Regular MaintenanceRemoving Nozzle Line for Service(Reference the Replacement Parts Diagram.)Use only nozzles havin
20Figure 11. – Nozzle Line/Head/Air Tube Assembly (Low fi ring rate shown.) Retention HeadRetention HeadHead Support LegsHead Support LegsElectrode Ti
21NX Burner ManualCheck/Adjust “Zero” CalibrationOn burners with factory-installed air tubes, the zero calibration has been factory set. Make sure th
22For best performance specify genuine Beckett replacement partsSection: Replacement PartsReplacement Parts
23NX Burner ManualItem Description Part No.1 Housing Specify **2 Head/Air adjustment mecha-nism assembly52000U3 Splined nut 36664 Coupling 24545 Clean
USA: P.O. Box 1289 ● Elyria, Ohio 44036Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7www.beckettcorp.comPart Nu
3NX Burner ManualTo the Owner:Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay attention to the Safety Warni
4General InformationSection: General InformationHazard Defi nitions Within the boundaries of the hazard warning, there will be information presented de
5NX Burner ManualSpecial RequirementsTHE INSTALLATION OF A BURNER SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF AUTHORITIES HAVING JURISDICTION.For r
6Inspect/Prepare Installation SitePlease read and understand the manual supplied with this equipment. This equipment must be installed, adjusted and p
7NX Burner ManualNo other appliance connection should be made to the same fl ue pipe.The fl ue pipe should have an upward pitch toward the chimney of at
8Combustion chamber — Burner retrofi ttingVerify that the appliance combustion chamber provides at least the minimum dimensions given in Table 3.○Chamb
9NX Burner ManualConnect Fuel LinesOil Leak and Fire HazardInstall the oil tank following applicable standards in the U.S. by referring to the latest
Comentarios a estos manuales