Beckett 7600 AquaSmart Boiler Control Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Beckett 7600 AquaSmart Boiler Control. Beckett 7600 AquaSmart Boiler Control User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PARTS & ACCESSORIES
Description / Applications
The Beckett AquaSmart™ is an advanced boiler control designed for use on
residential and light commercial boiler systems. All models include the option of
enabling Beckett HeatManager™ dynamic temperature reset that, when selected,
provides up to 20% fuel consumption savings. The control includes a backlit LCD
digital display with touch pad to easily program temperature limits, differentials,
and other advanced options. The AquaSmart™ also has memory storage of
system history for help with diagnostics and troubleshooting.
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Description / Applications

PARTS & ACCESSORIESDescription / ApplicationsThe Beckett AquaSmart™ is an advanced boiler control designed for use on residential and light commer

Pagina 2 - Table of Contents

10Figure 7 - Pin Engagement Cutawaye - No pin engagementf - As the probe is inserted, it comes in contact with the clip opening and there is some slig

Pagina 3 - Technical Specications

11AquaSmart Boiler Control ManualInstalling the AquaSmart Control (Refer back to Figure 3 for appropriate mounting method).Mounting to the Immersion W

Pagina 4 - Installation

12Wiring the AquaSmart Control ○ Consult the appliance wiring diagrams to check the manufacturer’s specications. ○ Refer to Figure 12 through Figure

Pagina 5

13AquaSmart Boiler Control ManualSK10030P1COLDWATERINLETEXPANSIONTANKHEATINGZONEAIRSEPARATORAIRVENTFigure 12 - 7600A/B single-zone connections with or

Pagina 6

14Figure 13 - 7600A/B multi-zone connections with or without a tankless coilWater Flow:Control Wiring (Option 1): Circulator-On and -Off Delays on Zon

Pagina 7

15AquaSmart Boiler Control ManualTRTWSK1003265432/N1/HTTZONERELAYZONE1LOW VOLTAGETHERMOSTATLOW VOLTAGETHERMOSTATZONE2ZONERELAYTT1/H2/N34NEUTRALHOT120

Pagina 8 - Installing the 2-in-1 Sensor

16Figure 14 - 7600A/B alternate multi-zone connections with or without a tankless coilWater Flow:Control Wiring (Option 1): 7600B onlyCAUTION - Always

Pagina 9

17AquaSmart Boiler Control ManualFigure 14 (continued) - 7600A/B alternate multi-zone connections with or without a tankless coilControl Wiring (Optio

Pagina 10 - Safety Function

18SK10034COLDWATERINLETEXPANSIONTANKAIRSEPARATORAIRVENTHEATINGZONE1INDIRECTDHWDHWZONEP2P1Figure 15 - 7600A/B single-zone connections with Indirect Dom

Pagina 11 - (Figure 9)

19AquaSmart Boiler Control ManualSK10035COLDWATERINLETEXPANSIONTANKAIRSEPARATORAIRVENTHEATINGZONE1INDIRECT DHWDHWZONEP1P2 P3HEATINGZONE2HEATINGZONE3*P

Pagina 12 - Wiring the AquaSmart Control

2 ○ HeatManager™ dynamic temperature reset for additional energy savings — DOE 2012 Compliant — Meets NR CAN proposed 2012 requirements ○ Advance

Pagina 13 - Control Wiring:

20Figure 16 (continued)- 7600A/B multi-zone connections with Indirect Domestic Hot Water (DHW)Control Wiring (Option 1): Circulator-On and -Off Delays

Pagina 14

21AquaSmart Boiler Control ManualL2 L1 C1 C2 ZC ZR B1 B2TRTWSK1002465432/N1/HTTZONERELAYLOW VOLTAGETHERMOSTATZONE1ZONERELAYTT1/H2/N3456NEUTRALHOT120 V

Pagina 15

22Figure 16 (continued) - 7600A/B multi-zone connections with Indirect Domestic Hot Water (DHW)◄ CONTINUED FROM PREVIOUS PAGEControl Wiring (Option 3)

Pagina 16 - CONTINUED ON NEXT PAGE ►

23AquaSmart Boiler Control ManualFigure 17 - 7600A/B alternate multi-zone connections with Indirect Domestic Hot Water (DHW)Water Flow:SK10037COLDWATE

Pagina 17

24Figure 17 (continued) - 7600A/B alternate multi-zone connections with Indirect Domestic Hot Water (DHW)Control Wiring (Option 1): 7600B onlyCAUTION

Pagina 18

25AquaSmart Boiler Control Manual◄ CONTINUED FROM PREVIOUS PAGEControl Wiring (Option 2): 7600A onlyCAUTION - Always observe proper polarity when conn

Pagina 19

26To ensure smooth appliance operation, the AquaSmart requires a separation between the High and Low limits no less than the greater differential plus

Pagina 20

27AquaSmart Boiler Control Manual3. Press the “ENTER (RESET)” key. 4. The control will ask you to conrm the setting with the following screen: HIGH

Pagina 21

283. Press the “ENTER (RESET)” key. The following screen will be displayed: 1 ON> 2:15OFF> 30:05 140FABCD4. To navigate the history

Pagina 22

29AquaSmart Boiler Control Manualc. To change the call for heat source that the circulator is activated from (see Figures 8 - 13 for examples), press

Pagina 23

3AquaSmart Boiler Control ManualFigure 1 - Getting to know the AquaSmart 7600 Series ControlTemperature Ranges and Differentials ○ High Limit Setting

Pagina 24

302. Press the “▲” and “▼” keys until the following screen is displayed:MORE OPTIONSENTER TO VIEW3. Press “ENTER (RESET)”. The following screen wil

Pagina 25

31AquaSmart Boiler Control ManualAquaSmart OperationTable 4 – Typical operation with default settings (Circulator set “ON TT”)System Action AquaSmart

Pagina 26 - Programming Basic Functions

3275501001251501752002252502753007550100125150175200225250275300How a Boiler Control WorksFigure 19 - Cold Start Operation (Low Limit ► OFF)Figure 20

Pagina 27

33AquaSmart Boiler Control ManualTroubleshootingLockoutThe AquaSmart will lock out if any number of abnormal conditions are detected.HeatManager Techn

Pagina 28 - Key (for steps B3 & B5):

34During Annual Maintenance or More Frequent Service Intervals, Verify the below items. Note: The 7600 control has no serviceable internal parts. DO

Pagina 29

35AquaSmart Boiler Control ManualSK10029Mounting TemplateTHIS END UPUse self-drilling screws supplied in the 7600RMU Remote Mount Kit-or-Drill 0.110”

Pagina 30

Form No. 61738 Rev. 11, Printed in USA 11/13USA: P.O. Box 1289 ● Elyria, OH 44036Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guel

Pagina 31 - AquaSmart Operation

4Figure 2 - Basic Dimensions (inches)MountingOEM Installation: When replacing an OEM-installed AquaSmart, consult the appliance manufacturer’s wiring

Pagina 32 - How a Boiler Control Works

5AquaSmart Boiler Control ManualAquaSmart Models and Cross-Reference GuideTable 1a - Direct ReplacementsHoneywellBeckett ReplacementNotesL7148F (All)

Pagina 33 - HeatManager Technology

6HoneywellBeckett ReplacementNotesL4081A/BL6081A/C7600A or 7600B (Based on System Voltage Requirements)Remove switching relay, if used, from the syste

Pagina 34 - Accessories

7AquaSmart Boiler Control Manual1. Compare the attached wires to available wiring diagrams on the control cover and to the devices to which they can

Pagina 35 - Mounting Template

8Installing the 2-in-1 SensorFor proper operation, there must be a secure electrical bond between the green sensor wire from the sensor and the boiler

Pagina 36 - Limited Warranty Information

9AquaSmart Boiler Control Manual2-in-1 “Integrated Unit” InstructionsThis is very important for successful control operation.1. Remove the existing i

Comentarios a estos manuales

Sin comentarios