Description / ApplicationsThe Beckett GeniSysTM Display is an optional attachment for the GeniSys Primary Control that allows a technician to monitor
10Screen Message Sensor/Monitor/MessageNotes/Checks### ohms avg Cad Cell Historical cycle data located in Control. Average Cad Cell resis-tance measu
11GeniSys Display & Contractor Tool Installation and Operation Manual
Form No. 61687 R05, Printed in USA 05/10CORPORATIONUSA: P.O. Box 1289 ● Elyria, OH 44036Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road
2InstallationWith a slotted screwdriver, carefully remove the COM2 port cover on the right side of the GeniSys control. When installing the display, s
3GeniSys Display & Contractor Tool Installation and Operation ManualThe display was designed to function as both a monitor and a programmer. The
4Standby - During this time, the burner is idle and waiting for a signal to turn on.Pre-time - The Pre-time screen will display the number of seconds
5GeniSys Display & Contractor Tool Installation and Operation ManualPressing the BACK (NO) key at this stage will return the display to the VIEW H
6►NEXTCycle End Reason* * The possible cycle end reasons are as follows, Recycled - The burner was shut down because
7GeniSys Display & Contractor Tool Installation and Operation ManualTo return to the CYCLE HISTORY screen, press BACK (NO) once. To return to the
8D. Post-time Set ProgramFrom the PRE-TIME, SELECT TO CHANGE screen, press the NEXT key to access the POST-TIME (motor off delay), SELECT TO CHANGE sc
9GeniSys Display & Contractor Tool Installation and Operation ManualE. Service Message ProgramFrom the POST-TIME CHANGE screen, pressing the NEXT